Agilent MSO9404A Oscilloscope,
4 GHz, 4-Analog Channels + 16-Digital Channels
Agilent’s Infiniium MSO9404A, equipped with a 15” XGA
display, comes in a package that is just 9” (23 cm) deep and
weighs only 26 pounds (11.8 kg) to preserve your limited bench space.
This scope is engineered to give you the broadest measurement capability
available to meet your needs both today and in the future. 16 fully
integrated, time-aligned digital channels give you insight into timing
relationships and allow precise triggering. Take advantage of optional
integrated protocol viewers to quickly isolate physical layer issues
causing errors. Customize your toolset with our debug and compliance
packages to tailor the scope to your needs.
HP/Agilent MSO9404A Features
- 4 GHz bandwidth across all 4 analog channels
- 20 GSa/s max. sample rate
- 4 analog channels + 16 digital channels
- Standard 20 Mpts per channel memory, upgradeable to 1 Gpts
- Scope: The powerful features of our Infiniium Series oscilloscopes
with InfiniiScan advanced triggering coupled with superior specifications
give you precise signal representation
- Logic Analyzer: Add 16 integrated, deep-memory digital channels
to see critical data values and timing relationships. Choose MSO9404A
- Protocol analyzer: Choose integrated protocol viewers to quickly
drill down into packets and time correlate between protocol and physical
layers.
- Serial protocol applications including I²C, SPI, RS-232, CAN,
LIN, FlexRay, JTAG, PCI Express, USB 2.0, MIPI D-Phy, SATA and 8B/10B
-
Serial physical layer applications including USB 2.0, DDR 1/2/3, Ethernet,
and MIPI D-Phy
- Jitter analysis applications including EZJIT
- MATLAB® software available
directly from Agilent for making your own custom measurement and
analysis routines, user-defined filters, or instrument applications.
HP/Agilent MSO9404A Standard Accessories
The following items are shipped by Global Test Equipment
with each unit ordered.
| Part Number |
Description |
Qty |
| |
Power Cord |
1 |
| 54904-97005 |
Service Guide |
1 |
| 54904-97006 |
User's Guide |
1 |
| 54904-97002 |
Programmer's Guide |
1 |
| N2873A |
500 MHz Passive Probe |
4 |
| 54904-62301 |
Accessory Pouch |
1 |
| 54904-44101 |
Front Panel Cover |
1 |
| |
Keyboard |
1 |
| |
Mouse |
1 |
| |
Stylus |
1 |
| 54904-61615 |
MSO Cable |
1 |
| 01650-61608 |
Flying Lead Set |
1 |
| |
Calibration Fixture |
1 |
OPTIONS***
| Option |
Description |
| 001 |
RS-232/UART Protocol Triggering and Decode - installed |
| 002 |
EZJIT jitter analysis software - installed |
| 003 |
High-Speed SDA and Clock Recovery - installed |
| 004 |
EZJIT Plus jitter analysis software - installed |
| 005 |
USB 2.0 Protocol Triggering and Decode - installed |
| 006 |
PCI e 1.1 Protocol Triggering and Decode - installed |
| 007 |
I2C/SPI Protocol Triggering and Decode - installed |
| 008 |
CAN, LIN, FlexRay Protocol Triggering and Decode - installed |
| 009 |
InfiniiScan - installed |
| 010 |
User-Defined Function - installed |
| 011 |
App Remote Programming Interface - installed |
| 012 |
Infiniium Signal Equalization - installed |
| 013 |
InfniiSim Basic - installed |
| 014 |
InfiniiSim Advanced - installed |
| 015 |
Power Measurement application software - installed |
| 016 |
Xilinx FPGA dynamic probe - installed |
| 017 |
Altera FPGA dynamic probe - installed |
| 018 |
Protocol triggering and decode for: I2C, SPI, and RS-232/UART-
installed |
| 019 |
MIPI D-Phy Protocol Triggering and Decode – installed |
| 021 |
Ethernet compliance application - installed |
| 029 |
USB2.0 compliance application - installed |
| 031 |
DDR and LPDDR Compliance Test Application – installed |
| 032 |
DDR2 and LPDDR2 Compliance Test Application – installed |
| 033 |
DDR3 up to 800MHz validation application - installed |
| 035 |
MIPI D-Phy Compliance application – installed |
| 038 |
SATA (1.5 Gbs) Triggering and Decode - installed |
| 040 |
User Defined Application -Installed |
| 042 |
JTAG Protocol Decode - installed |
| 061 |
MATLAB - Basic Digital Analysis Package |
| 062 |
MATLAB - Standard Digital Analysis Package |
| 100 |
Memory - 100Mpts/ch memory installed |
| 1CM |
Rack Mount Kit |
| 200 |
Memory - 200Mpts/ch memory installed |
| 500 |
Memory - 500Mpts/ch memory installed |
| 50M |
Memory - 50Mpts/ch memory installed |
| 801 |
Removable Hard Drive - installed |
| 820 |
DVD-RW drive |
*** The above list of options represents commonly found options. Units
available from Global Test Equipment may have a combination of these
options. Contact Us for detailed information
about the options available on the units in stock.
|
|