HP/Agilent E2443B Analysis Probe for the Intel Pentium® 510/60 MHz and 567/66 MHz - Buy, Rent, Lease, Sell or Trade

HP/Agilent E2443B Quote

Back To:
Logic Analyzers

Buy, Rent or Lease New or Used Equipment Today!

Sell or Trade Your Excess or Surplus Test Equipment!

NEED PARTS OR ACCESSORIES?
Click here to check our inventory.

Available MANUALS and SOFTWARE
Click here to check our inventory.

Clearance Inventory!
Click here to view products on clearance

Excess Equipment?
Click here to contact us regarding selling your equipment.

HP/Agilent E2443B Analysis Probe for the Intel Pentium® 510/60 MHz and 567/66 MHz

The Pentium analysis probe (formerly known as a preprocessor) has four modes of operations. In the state-per-transfer mode, the logic analyzer is clocked upon completing data transfer cycles. In this mode, the analysis probe keeps track of the address pipeline and aligns data with its parent address. Additionally, activity during an HLDA or BOFF# assertion is captured.

In the state-per-clock mode, data is captured on every system clock, so you see all processor activity including wait and idle states. This mode of operation is useful in finding memory locations that do not respond with data and in checking memory control systems.

In the timing analysis mode, all signals are buffered, but otherwise pass straight through to the logic analyzer.

The debugger mode is identical to state-per-transfer mode, except that whenever IU, IV or IBT are asserted, data is captured regardless of whether or not it is valid.

HP/Agilent E2443B Features

  • The logic analyzer captures all bus cycles, including prefetches, and marks unexecuted prefetches
  • Disassembly of floating point instructions is supported
  • Burst mode addresses are calculated and displayed in the state trace listing
  • Timing analysis is supported; all signals go through 6.4 ns maximum buffers
  • State-per-clock mode runs up to 100 MHz providing margin for testing
  • Preprocessor can be configured to prequalify the logic analyzer clock on BRDY#, ADS#, EADS#, BOFF# and HLDA, saving logic analyzer resources
  • Pentium is a U.S. registered trademark of Intel Corporation.
  • HP/Agilent E2443B Standard Accessories

    The following items are shipped by Global Test Equipment with each unit ordered.
    Part Number Description
    Qty
    E2443-90903 User Manual
    1


    Agilent Channel Partner Logo

    HOME
    Global Test Equipment, Inc., is your complete source for all of your global test supply needs!
    We stock thousands of manuals, parts and accessories for electronic test equipment!

    Global Test Equipment offers:

    Counters, Data Acquisition, Lightwave, Logic Analyzers, Meters, Microwave, Network Analyzers, Oscilloscopes, Power Supplies, RF, Signal Analyzers, Signal Generators, Spectrum Analyzers, Switches, Telecommunications, Test Accessories, VXI, Misc.

     
    ©2003 Global Test Equipment 1424 Centre Circle, Downers Grove, IL. 60515 (630) 678-0400 Fax: (630) 678-0404